Frantz Industrial Permanent Magnet Separators Page 2

 · Toll free 800-227-7642 • Ph. 215-943-2930 • Fax 215-943-2931 • E-mail [email protected]

Method and apparatus for magnetic separation of particles ...

Unlike other separators, the Frantz ISODYNAMIC separator employs an isodynamic magnetic field, i.e., a field which exerts a substantially constant force on a particle of given susceptibility regardless of the position of the particle within the field, and as a consequence is capable of making positive and quite fine separations.

1.6. Frantz Magnetic Separator — CSUN Rock Lab Manual …

 · 1.6.1.1. Set Up . Wipe down all areas around the Frantz and the nearby table with a damp paper towel to avoid contamination of your sample. Remove the cover over the Frantz, and wipe down any dusty areas of the machine with a slightly damp paper towel. Lay out a sheet of clean paper or foil on the table, and place 6 Dixie cups on this area.

The Frantz Magnetic Barrier Laboratory …

 · The rinsed and dried samples were passed through a Frantz magnetic separator (Porat, 2006) to remove any undissolved carbonates, heavy minerals, and some feldspars. A 40-min rinse in hydrofluoric ...

Model L-1 - S.G. Frantz

 · FRANTZ. MAGNETIC SEPARATOR. (Model L-1) Principles of design. The Isodynamic ® Separator consists essentially of an electromagnet having two long pole pieces shaped to a special contour (shown in simplified form in the sketch below) with a long narrow air gap between them. Materials to be separated are fed into one end of the magnetic field (1 ...

S.G. Frantz – 80 Years of Magnetic Separation Excellence

 · S.G. Frantz's standard proprietary grids are effective for most applications, exemplifying a principle revealed early by Mr. Frantz: For effective magnetic separation, the size of the collecting edge should be on the same order of magnitude as the size of the particles to be captured. This configuration offers several advantages: The width of the strip is aligned with …

Model Lb-1, page 2 - legacy.sgfrantz.com

 · The Frantz Isodynamic Magnetic Separator (FIMS) is a versatile instrument and can produce excellent concentrates of many minerals. Substantial literature has been published on the subject of mineral separations performed with the FIMS [Citations omitted]. The MBLS has a significant advantage over the FIMS in the ratio of magnetic force to field ...

(Solid Angle)

 ·  (Solid Angle) (Sphere Angle) Spherical Coordinates,2 : θϕ θ ϕ 。. :. 。. 3 …

Magnetic Seperation

 · The magnetic separator consists of a large electromagnet through which mineral mixtures can be passed on a metal trough which is divided near its exit end. Varying the strength of the magnetic field and/or slope of the separation trough is used to separate minerals. All forms of mineral separation suffer from one difficulty.

Magnetic separator - Frantz, G.

In the accompanying drawing: Fig.,1 is a vertical central section through a magnetic separator in accordance with my present invention. Fig. 2 is a top plan view of one of the attractor grids removed from the stack, and Fig. 3 is a diagram illustrating the action of my separator.

Products-JiuJie Machinery - magnetic separator s

Magnetic bar separator series Crusher series Vibrating feeder series Metal detector series Support equipment series Products world CTS (NB) Series wet Permanent Magnet Separator CTS(NB) Series wet magnetic separator JJECS Eddy Current Separator ...

Magnets, Electromagnets, and Eddy Current Separators | …

 · Its Magnetic Separator (which can use either a permanent or electromagnet), on the other hand, is designed for speed and efficiency. Set cross-angle to the main conveyor belt, the overhead electromagnet extracts steel, which then adheres to the upper belt. This allows for continuous removal of steel scrap.

() - -,(TMR ...

 · Biaxial TMR Angle Sensor 0~7 V 360 ° 7.5KΩ 1000 150~1100 Oe ±1.5° LGA8L(3×3×0.75) In stock TMR3005 — Biaxial TMR Angle Sensor 0~7 V 360° 140KΩ 340 200~800 Oe ±0.6° LGA8L(3×3×0.75 ...

LB-1 Magnetic Barrier Laboratory Separator – S.G. Frantz

 · Company founder G. Frantz pioneered the science of magnetic separation technology, engineering the Frantz ® Isodynamic Separator, which became the leading device for separation according to magnetic susceptibility.. Because the Frantz ® Isodynamic Separator has a virtually unlimited useful life, elements of the LB-1 Magnetic Barrier Laboratory Separator …

Methods and apparatus for separating particles using a ...

The larger sample was first passed in conventional fashion through a Model L1, Frantz ISODYNAMIC magnetic separator with the chute arranged to have a transverse slope to the left at an angle θ of 15° and a forward slope at an angle θ of 25°.

FRANTZ L-1 Isodynamic Magnetic Separator | 316196

 · Frantz Isodynamic Magnetic separator, Model L-1, table top. Input 115 Volts, 2.5 AMPS, 50/60 Hz, serial number 1770. Note: This is a dry high intensity magnetic separator. Used in minerals research and development lab.

Mineral Separation Techniques Frantz Magnetic Separator

In the Frantz separator, mineral particles are fed down a vibrating chute inclined at an angle 2 which is also inclined in the transverse direction at an angle 1. Magnetic separators can be found in most mineral processing operations, especially …

Frantz Isodynamic Separator (Model LB 1). | …

Download scientific diagram | Frantz Isodynamic Separator (Model LB 1). from publication: Comparative mineralogy and magnetic separation characteristics of Nb-Ta oxide minerals from rare-metal ...

Mineral separation laboratory | Department of …

 · Frantz magnetic separator: Magnetic separation is based on minerals` magnetic properties. Some of the largest and magnetic minerals (ferromagnetic minerals) are often removed via a handheld magnet before …

A Laboratory-Scale Magnetohydrostatic - USGS

 · The MHS separator described in this report (fig. 2) was constructed around a modified Frantz Isodynamic Separator1, which is used to provide the required magnetic field. The modifications are such that 1Use of brand or manufacturers' names in this report is for descriptive purposes only and does not constitute

Electromagnetic Separators – S.G. Frantz

 · S.G. Frantz Electromagnetic Separators. S.G. Frantz® Electromagnetic Separators utilize electric currents through wire coils in iron housings, which create magnetic fields to separate highly magnetic materials from liquids, gases, slurries and powders. Available in gravity, underfeed and pipeline models, our separators deliver outstanding ...

Frantz Industrial and Laboratory Magnetic Separators

 · Frantz ® Canister Separator. S. G. Frantz Co. Inc. offers laboratory separators and auxiliary equipment for: Continuous precise magnetic separation of dry materials by either paramagnetic or diamagnetic susceptibility, also by ferromagnetic properties. Bench scale high intensity, high gradient matrix separations of fluids and slurries.

Improved method for prediction of heavy metal recoveries ...

 · The equilibrium for the Frantz isodynamic separator (FIS) is given by: (2) g sin (θ)= χ ∇B 2 2μ o where θ is the transversal angle, and g is acceleration due to gravity (m/s 2). To calculate the apparent magnetic susceptibility of isolated soil fractions the following equation ( Frantz, 1936 ; McAndrew, 1957 ; Nesset and Finch, 1980 ) was ...

MINERAL SEPARATION AND PROVENANCE LAB …

 · magnetic from non-magnetic minerals isaccomplished using aFrantz isodynamic separator. 1.First, to remove the extremely magnetic minerals, such asmagnetite, from the heavy mineral fraction we will use afree-fall magnetic separation. Attach apaper cone tothe front of the Frantz which has had itsmagnet rotated into avertical position. Place abeaker

1USGS

 · Magnetic separator settings Magnetic separators used during the study were Frantz Isodynamic Magnetic Separators, Model L-l*. The original brass chute in each machine was replaced by an aluminum chute milled in the USGS machine shop. The isodynamic vibrator at the upper end of the chute was replaced by an asymmetric vibrator, as

Halconangle_llangle_lx - ni -

 · Halconangle_llangle_lx. Halconangle_llangle_lx(x),,。. 1. angle_ll(Row1 ...

Permanent Magnets Ltd

IFR Machine - Tea Filtration. Conveying Systems. Single Pole Suspended Permanent Magnets. Two Pole Suspended Permanent Magnets. Crosse Belt Separator. Magnetic Roller Separator. Pneumatic Pipeline. Pneumatic chute Magnet. Self Cleaning Atomized Systems.

Frantz Laboratory Magnetic Separators

 · Frantz ® Canister Separator (Model L-1CN) Provides a bench top high gradient, high intensity magnetic separator for processing liquid suspensions of fine particles. With the regulated power supply the magnetic field strength in the empty separating chamber is variable from 0 to approximately 15,500 - 16,000 Gauss. ...